SFABXETH is a DLL driver which allows a
Super-Flash application to communicate with Allen-Bradley controllers (Logix5000™ e SLC™ 500) via Ethernet/IP™.
The driver uses Ethernet/IP technology, the use of which is covered by the license granted to Automa by the Open DeviceNet Vendor Association (ODVA).
Description |
The SFABXETH driver allows a Super-Flash application to manage the Ethernet/IP™ (Ethernet/IP™ = CIP™ over Ethernet) communication with:
- Allen-Bradley Logix5000™ controllers, via native CIP™ messaging for access to Tags
- Allen-Bradley SLC™ 500 controllers, via PCCC messaging
|
Characteristics |
The features of SFABXETH are:
General:
-
communication with up to 100 Allen-Bradley controllers (Logix5000 e SLC500)
-
connection in "Direct Network Device" mode (connection to the controller via direct access to the Ethernet port of the controller itself)
-
connection in "CLX via backplane" mode (connection to the controller via a Ethernet communication module inserted in the backplane)
-
retries on the single channel in case of communication error
-
inactivity time on the single channel in case of communication error
Communication with Logix5000 controllers:
-
read/write of BOOL (1 bit) type resorces in single or array mode
-
read/write of SINT (8 bit) type resorces in single or array mode
-
read/write of INT (16 bit) type resorces in single or array mode
-
read/write of DINT (32 bit) type resorces in single or array mode
-
read/write of REAL (32 bit floating point) type resorces in single or array mode
Communication with SLC™ 500 controllers:
-
read/write of N file resources (16 bit)
-
read/write of N file resources (32 bit)
-
read/write of F file resources (32 bit floating point)
|
Limits |
-
The maximum number of Allen-Bradley controllers (Logix5000™ e SLC™ 500) you can connect to is 100
-
Connection in "bridging" mode is not managed (connection to the controller via access to another controller with bridge function)
-
If used in a Super-Flash application version 4.1 or earlier, the maximum length of the resource identifier (TagName) is 12 characters
-
It does not support access to structure fields (for Logix5000™)
-
It does not support Ethernet/IP™ communication with PLC5™ controllers
|
Minimum Requirements |
-
Windows 9X, NT4, 2000/XP Operating Systems
-
WRunfile 3.2
|
Product Contents |
The package supplied, available on CD or downloadable from this site in the FreeDownload section, contains:
-
SFABXETH 1.4 HF1 Driver (DLL)
-
Documentation: Operating Manual
-
Super-Flash demo application
-
Smartkey Drivers
|
 |
|